3 ways to evaluate the resistance of concrete to chloride ions ingress: ASTM C1202 “RCPT or Coulomb test”, Nordtest Build 492 or EN 12390-18 “Chloride Migration Coefficient”, and ASTM C1760 “Bulk Conductivity”.
The 8 channels PROOVE´it system, capable for testing from 5 to 60 Volts, can perform:
The “Rapid Chloride Permeability Test (RCPT)” or “Coulomb test” in accordance with ASTM C1202 or AASHTO T 277 by determining the total electrical charge passed through a saturated concrete specimen when an electrical potential across the specimen is applied
The “Chloride Migration Coefficient,” by measuring the penetration depth of chloride ions, after an electric potential is applied to the specimen in accordance with Nordtest Build 492 or EN 12390-18.
The Bulk Conductivity or Resistivity can be determined in accordance with ASTM C1760 if the current passing through a saturated concrete specimen is measured during 1 minute.
Easy to assemble, auto-seal measuring cells are available for the different tests.
Rapid Chloride Permeability Test.
The test results measured from concrete samples or cores taken from existing structures can be used for:
Ordering Numbers*
Item | Order # | Item | Order # | |
PROOVE´it power supply for 8 cells | PR-1050 | User manual | PR-1090 | |
PROOVE´it software for Windows® | PR-1040 | Spare steel mesh for cell | PR-1003 | |
Power cable for power supply 230 VAC | PR-1064 | Verification unit | PR-1055 | |
Power cable for power supply 110 VAC | PR-1065 | Vacuum desiccator for max. 16 specimens | PR-1070 | |
RS-232C serial cable for power supply | PR-1066 | Vacuum pump, < 50 mm Hg (6.7 kPa) | PR-1080 | |
PROOVE´it cell, standard | PR-1000 | Vacuum pump, < 10 mm Hg (1.3 kPa) | PR-1081 | |
PROOVE´it cell, with cooling fins | PR-1100 | CORECASE for 100 mm cores | CEL-100 | |
PROOVE´it cell for bulk conductivity | PR-1200 | Drilling machine, 1150W | CC-29 | |
PROOVE´it cell for bulk conductivity | PR-1000-113-20 | Diamond saw for trimming cores | PR-1090 | |
Red connecting cord, one per cell | PR-1001 | 300 mL bottle of 3.0 % NaCl solution | PR-1020 | |
Black connecting cord, one per cell | PR-1002 | 300 mL bottle of 0.3N NaOH solution | PR-1030 | |
Temperature probe, one per cell | PR-1005 | Precision steel mold, reusable | MRLN-1009 |
*These items can be selected as needed to assemble a system to meet the desired requirements
Measuring cells:
Rapid Chloride Permeability Test.
EN 12390-18: Testing hardened concrete – Part 18: Determination of the chloride migration coefficient.
| Cookie | Duration | Description |
|---|---|---|
| cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
| cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
| cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
| cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
| cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
| viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |